{"id":12285,"date":"2025-04-15T15:32:41","date_gmt":"2025-04-15T13:32:41","guid":{"rendered":"https:\/\/www.dovac.nl\/single-stage-vs-two-stage-side-channel-blowers-which-blower-best-suits-your-application\/"},"modified":"2025-10-23T15:57:02","modified_gmt":"2025-10-23T13:57:02","slug":"single-stage-vs-two-stage-side-channel-blowers-which-blower-best-suits-your-application","status":"publish","type":"post","link":"https:\/\/www.dovac.nl\/en\/single-stage-vs-two-stage-side-channel-blowers-which-blower-best-suits-your-application\/","title":{"rendered":"Single-stage vs. two-stage side channel blowers: which blower best suits your application?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">If you are looking for a side channel fan &#8211; or blower &#8211; for an industrial application, you will soon find out that there are several different versions. One of the first choices you have to make is: do you choose a single-stage or a two-stage side channel blower? <\/p>\n\n<p class=\"wp-block-paragraph\">This may sound like a small detail, but in practice, this difference matters quite a lot. Not only for the performance of your system, but also for its longevity, energy consumption and reliability. <\/p>\n\n<p class=\"wp-block-paragraph\">In this blog, we take you into the world of side channel blowers. We will calmly explain the characteristics of these blowers, what exactly is the difference between single-stage and two-stage side channel blowers, and of course: which one fits your application best? <\/p>\n\n<p class=\"wp-block-paragraph\">And to make it a little more concrete? We share two real-life examples &#8211; from the logistics and wellness worlds &#8211; where choosing the right blower really made the difference. <\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p class=\"wp-block-paragraph\"><strong>What exactly is a side channel fan?<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">Let&#8217;s start at the beginning. A <g id=\"gid_0\">side channel blower<\/g> is a type of blower that moves air or gas through a rotating impeller and side channels. Unlike, say, a centrifugal fan, side channel blowers are primarily about reliability, constant airflow and relatively low maintenance.  <\/p>\n\n<p class=\"wp-block-paragraph\">They are widely used in a variety of industries, think of:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Vacuum lifters<\/li>\n\n\n\n<li>Aeration of water (swimming pools, Jacuzzis)<\/li>\n\n\n\n<li>Pneumatic conveying<\/li>\n\n\n\n<li>Air transportation in production processes<\/li>\n\n\n\n<li>Suction of dust or air in installations<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">But within the side channel fan range, you again have a choice of single-stage or two-stage versions.<\/p>\n\n<p class=\"wp-block-paragraph\">And that&#8217;s exactly where the first questions often arise.<\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p class=\"wp-block-paragraph\"><strong>The difference between single-stage and two-stage side channel fans<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">The main difference between single-stage and two-stage blowers is in the way the air is moved and pressurized.<\/p>\n\n<p class=\"wp-block-paragraph\">A single-stage blower has &#8211; as the name implies &#8211; one impeller. The air is passed through the impeller once and then moves to the exhaust. <\/p>\n\n<p class=\"wp-block-paragraph\">A two-stage blower has two impellers in a row. This means that the air is sucked in first, compressed a little, and then passes a second impeller once more. This creates a higher pressure, but the air displacement (the flow rate) is somewhat lower.  <\/p>\n\n<p class=\"wp-block-paragraph\"><strong>In brief:<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.dovac.nl\/vacuumpompen\/oliegesmeerd\/\">Single-stage side channel fan<\/a> \u2192 lots of air, low pressure<\/li>\n\n\n\n<li><a href=\"https:\/\/www.dovac.nl\/vacuumpompen\/oliegesmeerd-tweetraps\/\">Two-stage side channel fan<\/a> \u2192 less air, but much higher pressure<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">But when do you choose what?<\/p>\n\n<p class=\"wp-block-paragraph\">We would like to explain this using two practical examples.<\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p class=\"wp-block-paragraph\"><strong>Case study 1: Vacuum charging in logistics<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">Vacuum lifters are a well-known example of an application where a two-stage side channel fan is indispensable.<\/p>\n\n<p class=\"wp-block-paragraph\">For example, we came to a customer in the logistics industry. They were working with vacuum lifters to lift heavy bags. Sounds simple, but those bags had a somewhat rough, porous exterior. As a result, there was always a little bit of leakage at the suction cups.   <\/p>\n\n<p class=\"wp-block-paragraph\">With a single-stage blower, it failed to generate sufficient vacuum. As soon as a bag moved slightly or skewed, the system lost power too quickly. <\/p>\n\n<p class=\"wp-block-paragraph\">The solution? A two-stage side channel blower. This blower could build much higher negative pressure and was powerful enough to lift the bags quickly and safely &#8211; even with small leaks in the system.  <\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Important advantages in this situation:<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>High vacuum in case of leakage<\/li>\n\n\n\n<li>Fast vacuum building<\/li>\n\n\n\n<li>Safe operation<\/li>\n\n\n\n<li>Reliability in daily use<\/li>\n<\/ul>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p class=\"wp-block-paragraph\"><strong>Case study 2: Aeration of Jacuzzis in a hotel spa<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">A very different application &#8211; but equally important &#8211; we find in the wellness sector.<\/p>\n\n<p class=\"wp-block-paragraph\">For a hotel with several luxury Jacuzzis, we were asked to supply the blowers for the aeration. This is all about experience: powerful air bubbles in the water, without disturbing noise from the technology in the background. <\/p>\n\n<p class=\"wp-block-paragraph\">Because the pipes were short and there was little resistance in the system, we chose a single-stage side channel blower here. Perfectly suited because a single-stage blower moves a lot of air at a low pressure. <\/p>\n\n<p class=\"wp-block-paragraph\">The result? Jacuzzis with powerful bubbling action, whisper-quiet blowers and energy-efficient installation. <\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Important advantages in this situation:<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>High air displacement<\/li>\n\n\n\n<li>Quiet in use<\/li>\n\n\n\n<li>Low energy consumption<\/li>\n\n\n\n<li>Perfect for aeration without much resistance<\/li>\n<\/ul>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p class=\"wp-block-paragraph\"><strong>Now when do you choose which blower?<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">Very simply put:<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Application<\/strong><\/td><td><strong>Best choice<\/strong><\/td><\/tr><\/thead><tbody><tr><td>Lots of air, little resistance<\/td><td>Single-stage side channel fan<\/td><\/tr><tr><td>High pressure, vacuum, high resistance<\/td><td>Two-stage side channel fan<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">But practice, of course, is always just a little more nuanced. Factors such as pipe length, filters, bends and required capacity all play a role. <\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p class=\"wp-block-paragraph\"><strong>Need help? We are happy to think with you.<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\"><strong>About DOVAC<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">DOVAC is a specialist in vacuum technology, blowers and industrial air applications. We supply a wide range of <a href=\"https:\/\/www.dovac.nl\/zijkanaalventilatoren\/\">side channel blowers<\/a>, <a href=\"https:\/\/www.dovac.nl\/vacuumpompen\/\">vacuum pumps<\/a> and <a href=\"https:\/\/www.dovac.nl\/parts-onderdelen\/\">spare parts<\/a> for various industries. <\/p>\n\n<p class=\"wp-block-paragraph\">With personal advice, technical support and a large inventory, we will help you quickly and competently.<\/p>\n\n<p class=\"wp-block-paragraph\">Would you like to know more about our products or a customized advice? Please feel free to contact us. <\/p>\n\n<p class=\"wp-block-paragraph\">\u2192 <a href=\"https:\/\/www.dovac.nl\/vacuumpompen\/\">View our range of blowers and vacuum pumps<\/a><br\/>\u2192 <a href=\"https:\/\/www.dovac.nl\/contact\/\">Or contact our specialists directly<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you are looking for a side channel fan &#8211; or blower &#8211; for an industrial application, you will soon find out that there are several different versions. One of&#8230;<\/p>\n","protected":false},"author":3,"featured_media":3203,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[62],"tags":[],"class_list":["post-12285","post","type-post","status-publish","format-standard","has-post-thumbnail","category-all-dovac-blogs"],"_links":{"self":[{"href":"https:\/\/www.dovac.nl\/en\/wp-json\/wp\/v2\/posts\/12285","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dovac.nl\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dovac.nl\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dovac.nl\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dovac.nl\/en\/wp-json\/wp\/v2\/comments?post=12285"}],"version-history":[{"count":1,"href":"https:\/\/www.dovac.nl\/en\/wp-json\/wp\/v2\/posts\/12285\/revisions"}],"predecessor-version":[{"id":12287,"href":"https:\/\/www.dovac.nl\/en\/wp-json\/wp\/v2\/posts\/12285\/revisions\/12287"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dovac.nl\/en\/wp-json\/wp\/v2\/media\/3203"}],"wp:attachment":[{"href":"https:\/\/www.dovac.nl\/en\/wp-json\/wp\/v2\/media?parent=12285"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dovac.nl\/en\/wp-json\/wp\/v2\/categories?post=12285"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dovac.nl\/en\/wp-json\/wp\/v2\/tags?post=12285"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}